What aux heat actually is

A heat pump moves heat — it does not create it. Below a certain outdoor temperature the pump cannot pull enough heat from the air to keep up, so electric resistance strips inside the air handler take over — basically a giant toaster element. That is "AUX" or "EM HEAT" on your thermostat.

The efficiency difference is the whole story: a heat pump delivers roughly 2–3 units of heat per unit of electricity. Resistance strips deliver exactly 1. When aux runs, you are paying two to three times more for the same warmth.

When aux is supposed to run

  • Defrost cycles — the outdoor unit periodically melts frost off its coil; aux covers the gap for a few minutes so you do not feel cold air. Normal, several times a day in damp cold
  • Below the balance point — the temperature where the pump alone cannot keep up, often somewhere in the 20s. Aux supplements — it should top off, not take over
  • Big thermostat jumps — bump the stat up 3+ degrees at once and many systems call aux to catch up fast. This is the one people trigger accidentally
  • Emergency heat mode — you switched it on manually. It runs everything through the strips at full cost until you switch back

When aux means a real problem

If AUX is showing constantly during mild weather — 35° and up — something is wrong:

  • Outdoor unit not running — failed compressor, capacitor, or a tripped disconnect; the strips carry the whole house at strip prices
  • Low refrigerant — the pump runs but cannot move enough heat, so aux fills in around the clock
  • Defrost board or sensor fault — the system thinks it is colder than it is
  • Undersized for the house — an addition or a leaky envelope means the balance point is effectively higher than it should be

The tell on the bill: an aux-heavy month can run double a normal one. If your January bill looks like your July bill — call.

How to keep aux from eating your paycheck

  • Set it and leave it — heat pumps like steady temps. Every big setback-and-recover cycle fires aux to climb back
  • Let the smart stat recover gradually — most learn to start early and avoid aux entirely; if yours keeps firing aux on recovery, check for a "heat pump balance" or "aux lockout" setting
  • Never use EM HEAT as normal heat — it is for a failed outdoor unit, not a cold Tuesday
  • Change the filter — restricted airflow pushes the system toward aux faster

Aux showing constantly in mild weather, or outdoor unit silent while aux runs? Call or text (267) 227-8115 — that is usually a real fault, and it is cheaper to fix than to heat your house with strips for a month. See our heat pump service page and the PA winter heat pump guide.